Analysis of the Stress-Strain State of the Wing of Hip Bone Using Various Types of Assembly Fixture of External Fixation Device for Elongation of the Femur

A.A. Tyazhelov, A.V. Yaresko, M.Yu. Karpinsky, P.N. Fedulichev, L.D. Goncharova, A.A. Kuznetsov

Abstract


The paper presents the results of studies of the peculiarities of mechanical interaction of assembly fixture of external fixation device for femur elongation with the wing of hip bone. A variant of the upgraded pelvic node compared to the original version is considered. The comparative analysis of the distribution of the stress level by the control points of models with a locking screw and without has been carried out. Stress-strain state of models under the influence of four type of loading has been studied. The material presented was clinically tested, has proved its utility and improved aesthetic appeal of surgery.


Keywords


intraosseous device; distraction; hip; pelvic node; strength; model

References


Березовский В.А., Колотилов Н.Н. Биофизические характеристики тканей человека: Справочник. — К.: Наукова думка, 1990. — 224 с.

Драган В.В. Одновременное удлинение обоих бедер полностью имплантируемыми управляемыми аппаратами Блискунова: Дис… канд. мед. наук: 14.00.22 / Драган Владимир Владимирович. — Симферополь, 1995. — 219 с.

Драган В.В. Удлинение длинных костей нижних конечностей приводными внутрикостными аппаратами: Дис… д-ра мед. наук: 14.01.21 / Драган Владимир Владимирович. — Донецк, 2009. — 89 с.

Зенкевич О.К. Метод конечных элементов в технике. — М.: Мир, 1978. — 519 с.

Ткач А.В. Аналіз помилок та ускладнень при подовженні стегна апаратами Бліскунова: Дис... канд. мед. наук: спец. 14.01.21 «Ортопедія-травматологія» / Ткач Андрій Вікторович. — К., 2003. — 199 с.

Попков А.В. Удлинение бедра с помощью интрамедуллярного стержня Albizzia / Попков А.В., Guichet J.-M., Lascombes P. // Гений ортопедии. — 2001. — № 1. — С. 16-25.

Cole J. Dean The intramedullary skeletal kinetic distraction (ISKD): first clinical results of a new intramedullary nail for lengthening of the femur and tibia / Cole Dean J., Justin Daniel, Tagus Hasparis // Injury. — 2001. — Vol. 32 (Suppl. 4). — P. 129-139.

Singh S. Results of limb lengthening by callus distraction using an extending intramedullary nail (Fitbone) in non-traumatic disorders / Singh S., Lahiri S., Iqbal M. // J. Bone Jt. Surg. — 2006.




DOI: https://doi.org/10.22141/1608-1706.1.14.2013.88858